Analytical Food Microbiology. Ahmed E. Yousef

Analytical Food Microbiology - Ahmed E. Yousef


Скачать книгу
count, etc.

       Population count should be presented in scientific notation, with two significant digits only reported (e.g., 3.7×108).

       In all examples presented, population count was based on unit food weight (g); however, samples of many liquid foods are measured volumetrically. In the latter case, population count is more accurately represented as CFU/ml.

      Principles

      Scoring the Tubes and Calculating MPN

Number of positive tubes MPN/g Number of positive tubes MPN/g Number of positive tubes MPN/g Number of positive tubes MPN/g
0.1 g 0.01 g 0.001 g 0.1 g 0.01 g 0.001 g 0.1 g 0.01 g 0.001 g 0.1 g 0.01 g 0.001 g
0 0 0 <3 1 0 0 3.6 2 0 0 9.2 3 0 0 23
0 0 1 3 1 0 1 7.2 2 0 1 14 3 0 1 38
0 0 2 6 1 0 2 11 2 0 2 20 3 0 2 64
0 0 3 9 1 0 3 15 2 0 3 26 3 0 3 95
0 1 0 3 1 1 0 7.4 2 1 0 15 3 1 0 43
0 1 1 6.1 1