ASME Steam Tables Compact Edition. ASME
CRTD-Vol. 83
ASME
Steam Tables
COMPACT EDITION
Properties of Saturated and Superheated
Steam in U.S. Customary and
SI Units from the IAPWS-IF97
International Standard for Industrial Use
Prepared by the ASME Research and Technology Committee on Water and Steam in Thermal Systems, Subcommittee on Properties of Steam
ASME • Three Park Avenue, New York, NY 10016
© 2006 by ASME, Three Park Avenue, New York, NY 10016, USA (www.asme.org)
ISBN: 0-7918-0254-X
ASME Order No. 80254X
All rights reserved. Printed in the United States of America. Except as permitted under the United States Copyright Act of 1976, no part of this publication may be reproduced or distributed in any form or by any means, or stored in a database or retrieval system, without the prior written permission of the publisher.
INFORMATION CONTAINED IN THIS WORK HAS BEEN OBTAINED BY THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS FROM SOURCES BELIEVED TO BE RELIABLE. HOWEVER, NEITHER ASME NOR ITS AUTHORS OR EDITORS GUARANTEE THE ACCURACY OR COMPLETENESS OF ANY INFORMATION PUBLISHED IN THIS WORK. NEITHER ASME NOR ITS AUTHORS AND EDITORS SHALL BE RESPONSIBLE FOR ANY ERRORS, OMISSIONS, OR DAMAGES ARISING OUT OF THE USE OF THIS INFORMATION. THE WORK IS PUBLISHED WITH THE UNDERSTANDING THAT ASME AND ITS AUTHORS AND EDITORS ARE SUPPLYING INFORMATION BUT ARE NOT ATTEMPTING TO RENDER ENGINEERING OR OTHER PROFESSIONAL SERVICES. IF SUCH ENGINEERING OR PROFESSIONAL SERVICES ARE REQUIRED, THE ASSISTANCE OF AN APPROPRIATE PROFESSIONAL SHOULD BE SOUGHT.
ASME shall not be responsible for statements or opinions advanced in papers or . . . printed in its publications (B7.1.3). Statement from the Bylaws.
For authorization to photocopy material for internal or personal use under those circumstances not falling within the fair use provisions of the Copyright Act, contact the Copyright Clearance Center (CCC), 222 Rosewood Drive, Danvers, MA 01923, tel: 978-750-8400, www.copyright.com.
CONTENTS
U.S. Customary Units
Table 1. Saturated Water and Steam: Temperature Table
Table 2. Saturated Water and Steam: Pressure Table
Table 3. Superheated Steam (1 to 15,000 psia)
SI Units
Table 4. Saturated Water and Steam: Temperature Table
Table 5. Saturated Water and Steam: Pressure Table
Table 6. Superheated Steam (0.005 to 100 MPa)
Unit Conversion Factors
Mollier Diagrams (U.S. and SI units)
This booklet is a product of the Properties Subcommittee of the ASME Research and Technology Committee on Water and Steam in Thermal Systems. The properties are computed from the “IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam,” adopted for industrial use by the International Association for the Properties of Steam (IAPWS). More comprehensive tables and charts from this formulation are published in: W.T. Parry, J.C. Bellows, J.S. Gallagher, and A.H. Harvey, ASME International Steam Tables for Industrial Use (ASME Press, New York, 2000). Software implementing this formulation is also available from ASME under the title ASME Steam Properties for Industrial Use.
REFERENCE STATE
By convention, the specific internal energy and specific entropy are defined to be exactly zero for the liquid phase of water at its triple point.
Table 1. Properties of Saturated Water and Steam (Temperature) | ||||||||
Temp. | Pressure | Volume, ft3/lbm | Enthalpy, Btu/lbm | Entropy, Btu/(lbm-°R) | Temp. | |||
°F | psia | v L | v V | h L | h V | s L | s V | °F |
32 | 0.08865 | 0.016022 | 3302.0 | -0.018 | 1075.2 | 0.0000 | 2.1868 | 32 |
35 | 0.09998 | 0.016020 | 2945.5 | 3.004 | 1076.5 | 0.0061 | 2.1762 | 35 |
40 | 0.12173 | 0.016020 | 2443.4 | 8.032 | 1078.7 | 0.0162 | 2.1590 | 40 |
45 | 0.14757 | 0.016021 | 2035.6 | 13.052 | 1080.9 | 0.0262 | 2.1421 | 45 |
50 | 0.17813 | 0.016024 | 1702.9 | 18.066 | 1083.1 | 0.0361 | 2.1257 | 50 |
55 | 0.21414 | 0.016029 | 1430.3 | 23.074 | 1085.3 | 0.0459 | 2.1097 | 55 |
60 | 0.25639 | 0.016035 | 1206.1 | 28.079 | 1087.4 | 0.0555 |