Transporters and Drug-Metabolizing Enzymes in Drug Toxicity. Albert P. Li

Transporters and Drug-Metabolizing Enzymes in Drug Toxicity - Albert P. Li


Скачать книгу
not associated with this [13]. Moreover, extensive hepatic metabolism has been associated with a higher risk of hepatic adverse events from oral medications [14]. High daily dose and extensive drug metabolism in the liver are associated with high risk of DILI, supporting the hypothesis that the formation and accumulation of RMs beyond a critical threshold is the precondition triggering the development of liver injury.

      The quantitative relationship between daily dose, formation of RMs and risk of DILI in humans was reported by Chen et al. [15]. By considering N = 354 FDA‐approved oral medications, the authors defined an algorithm for assigning a DILI score by factoring the relative contribution of daily dose, logP and RM, which permitted a quantitative assessment of clinical DILI risk:

equation

      The three parameters in the DILIscore formula (i.e. daily dose/Cmax, logP, and RM formation) contributed significantly to DILI risk with the order of RM > daily dose > logP. The relationship between calculated DILI scores and DILI risk was validated by three independent datasets retrieved from the literature, and the score model demonstrates its correlation with the severity of clinical outcome by applying to N = 159 clinical cases collected from the NIH’s LiverTox database (https://www.ncbi.nlm.nih.gov/books/NBK547852/).

      2.3.3 Structural Alerts for Avoiding Reactive Metabolites

      A compound’s potential to form electrophiles and chemically RMs is determined by its chemical structure. Certain functional groups, referred to as structural alerts, are molecular fragments with high chemical reactivity, or which can be transformed into fragments with high chemical reactivity through bioactivation [16]. These structural alerts can be present in the parent compound or in its metabolites.

      An increasing concern, however, is that the value of incorporating structural alerts for screening drug molecule‐associated safety hazards may have been overstated. In a study examining the role of RMs, about 50% of the top 200 drugs marketed in the U.S. and ranked by prescription and sales were found to have one or more alerts in their chemical architecture [17]. Meanwhile, the absence of structural alerts cannot serve as a guarantee of drug safety. For example, ximelagatran did not present any alerts in its chemical structure but was recalled as a thrombin inhibitor with idiosyncratic hepatotoxicity [17].

Schematic illustration of a few typical structure alerts for formation of reactive metabolites found in the literature.

      2.3.4 Experimental Approaches for Assessing Reactive Metabolites

      The structural alerts for formation of RMs sometimes do not imply actual formation of RMs. In this circumstance, experimental evidence is needed to assess whether a drug candidate is bioactivated to RMs. We discuss some selected experimental approaches here, including covalent binding assay, electrophile trapping experiment and time‐dependent inactivation of CYP450.

      2.3.4.1 Covalent Binding Assay

      The earliest approach for assessing protein covalent binding is using radiolabeled compounds with human liver microsomal or hepatocyte incubations. It is the gold‐standard approach for measuring RM formation and can quantify the extent of RMs covalently binding to proteins. The original experimental protocol for determining covalent binding properties of radioactive drugs was developed by Evans et al. [20]. In their protocol in vitro human liver microsomes are used as the metabolizing enzyme source and incubated with radioactive drug and cofactors for oxidative metabolism. Quantification of covalent binding is measured through counting the radioactivity of the protein pellet.

      Although the covalent binding assay is reliable and widely used by pharmaceutical companies, the use of radiolabeled drugs makes running high throughput screening difficult, and it is an expensive option for assessing whether a compound is likely to undergo bioactivation. A more common and economical screening approach is using electrophile trapping experiments that do not require radiolabeled drugs.

      2.3.4.2 Electrophile Trapping Experiments

      Following in vitro incubations, various analytical approaches such as LC‐MS, fluorescence or radiochemical detection could be used to analyze the trapped adducts and/or conjugates of RMs. Mass spectrometric methods are the most common approach. Taking advantage of specific fragmentation behavior of the peptide moiety of nucleophilic trapping reagents, stable trapping adducts, and/or conjugates of electrophilic RMs can be detected and characterized. For example, the neutral loss of 129 Da is commonly used by positive ion electrospray‐tandem mass spectrometry to provide a generic endpoint for GSH trapping and measurement. Without using the radiolabeled drugs, this protocol can provide semi‐quantitative estimates of adduct formation for RMs.

      2.3.4.3 Time Dependent Inactivation of CYP450 Enzymes

      Occasionally the formed RMs (electrophiles) are so highly reactive that they cannot flow out from the active site of the P450 enzymes that catalyzed their formation. Electrophilic intermediates derived from drug molecules are so reactive that they can covalently bind directly to an active site amino acid residue in the CYP enzyme itself. Covalent modification in the active site of a P450 enzyme may lead to the loss of enzyme activity over time via the modification of the P450 apoprotein.


Скачать книгу