Spectroscopy for Materials Characterization. Группа авторов

Spectroscopy for Materials Characterization - Группа авторов


Скачать книгу
counterpart of infrared absorption experiments [56, 57]. Similar to TRR, infrared TA can also probe the vibrational mode structure, but one advantage of TRR spectroscopy is the exclusive use of visible‐ or near‐infrared‐light pulses, which are easier to generate and detect, especially if broadband pulses are needed. Furthermore, due to the higher energy, visible‐light pulses are inherently shorter in time, ultimately providing better time resolution [51]. Another alternative is given by time‐domain techniques founded on TA, such as impulsive stimulated Raman scattering (ISRC) [58], which works best with low‐frequency modes and generally displays lower signal‐to‐noise ratios than state‐of‐the‐art TRR. For these reasons, TRR is generally recognized as the most powerful approach to achieve vibrational spectroscopy with femtosecond resolution, and will be discussed in detail in the rest of this section.

      3.5.2 Typical Experimental Setups

      The simplest and most straightforward path to implement a TRR experiment is to use a pump–probe approach very similar to TA experiment, except for the fact that the probe beam is used as a Raman pump. Thus, instead of measuring the change in probe transmittance, which is the basis of TA, one can achieve TRR by collecting the isotropic Raman signal produced by scattering of the delayed probe pulse, and analyzing it in a spectrograph as a function of pump–probe delay [54]. However, this method, named probe‐induced Raman scattering, is made very difficult by the very small cross section of Raman scattering, and also brings inherent limitations in time resolution. In fact, considering the time–energy uncertainty relation, the probe beam used as a Raman pump beam must be relatively broad in time to be narrow enough in the spectral domain. For example, a pulse centered at 550 nm, with a FWHM of 1 nm will guarantee a ω V spectral resolution of ∼30 cm−1, which may be adequate to probe a Raman spectrum, but with a transform‐limited pulse duration as long as 450 fs. This problem is fundamentally unsurmountable and limits the time resolution to the picosecond range.

      In fact, one of the most effective approaches to carry out a TRR experiment is use a more complex scheme, initially proposed at the end of the 1990s [55], based on what is called the stimulated Raman process. The relation between spontaneous and stimulated Raman process is similar to that between spontaneous and stimulated emission: shortly, the Raman scattering cross section into a given photon mode is strongly enhanced whenever that particular mode is already populated by photons provided by a seed beam. Therefore, stimulated Raman process can be used to probe the same properties as spontaneous Raman process, but with potentially much stronger intensity.

Image described by caption

      Source: Reprinted with permission from [55]. Copyright (1999) by the American Physical Society.

      Panel (b): Energy level diagram for time‐resolved stimulated Raman.

      Source: Adapted with permission from McCamant et al. [60]. Copyright (2003) American Chemical Society.

      Panel (c): One of the earliest time‐resolved stimulated experiment, probing the trans‐cis photoisomerization dynamics of 4‐(dicyanomethylene)‐2‐methyl‐6‐(4‐dimethylaminostyryl)‐4H‐pyran, dissolved in a 3 mM concentration in DMSO and photoexcited at 397 nm. The Raman pump pulse was tuned at 795 nm (bandwidth 1.5 nm), while the Raman probe pulse, obtained by supercontinuum generation, covered the region 600–1000 nm. Arrows indicate the Raman signals appearing due to the photogenerated transient states, while asterisks indicate the Raman lines of the solvent.

      Source: Reprinted figure with permission from Yoshizawa and Kurosawa [55]. Copyright (1999) by the American Physical Society.

      What is more important, however, is that the use of this detection approach provides the trick to achieve very high temporal resolution [61]. In fact, despite Raman scattering occurring during the whole duration of the Raman pump pulse (∼1 ps or more), it is only within the duration of the short‐lived Raman probe beam that stimulated Raman process occurs. Therefore, the time resolution of the measurement is now controlled by the femtosecond duration of the probe pulse. For example, a narrowband Raman pump pulse at 560 nm, with duration of several picoseconds, can be combined with a probe pulse centered, say, at 580 nm with a FWHM of 20 nm, which is broad enough to stimulate Raman emission over a relatively wide spectral range (∼1000 cm−1), and can be compressed down to <25 fs.

      While femtosecond stimulated Raman can be used as a way to record a ground state Raman spectrum, the final goal of these experiments is usually following the evolution initiated by the actinic pump, with time resolution given by the cross‐correlation of the actinic and Raman probe pulses, which can reach a few tens of femtoseconds. To do so, the stimulated Raman spectrum for the unexcited sample is compared to that obtained at variable delays from photoexcitation, in order to follow the effect of relaxation. The result of the experiment can be plotted either in terms of an absolute, time‐dependent Raman spectrum (e.g. as in Figure 3.6c), which contains both the features of the unexcited ground molecules and those of the excited molecules, or as a difference Raman spectrum, calculated with respect to the unexcited sample.


Скачать книгу